Status:
UNKNOWN
Paradigm I Clinical Trial: Study of the PFX Closure System in Subjects With Cryptogenic Stroke, Transient Ischemia Attack or Paradoxical Embolism
Lead Sponsor:
Cierra
Conditions:
Patent Foramen Ovale
Eligibility:
All Genders
18-65 years
Phase:
NA
Brief Summary
The primary objective of this study is to demonstrate the safety of the PFX Closure System when utilized for patients with patent foramen ovale (PFO) suffering from cryptogenic stroke, transient ische...
Detailed Description
Patent Foramen Ovale has been implicated in the etiology of paradoxical embolism, cryptogenic stroke, transient ischemic attack (TIA), and right to left gas embolism in severe decompression illness. A...
Eligibility Criteria
Inclusion
- Subject is between 18 and 65 years old.
- Documented patent foramen ovale as determined by positive micro bubble study demonstrating right to left shunt and/or anatomic detection and functional assessment by pre-operative TCD and peri-operative echocardiography or ultrasound.
- Subjects with a history of cryptogenic stroke, transient ischemic attack or paradoxical embolism due to presumed paradoxical embolism through a PFO.
- Negative pregnancy test in women who are of child-bearing potential.
- Signed Informed Consent form.
Exclusion
- Presence of thrombus at the intended site of closure, in left atrial appendage, or documented evidence of venous thrombus in the vessels through which access to the PFO is gained.
- Active endocarditis, or other infections producing a bacteremia.
- Presence of atrial septal defects or fenestrations which allow right-to-left shunting.
- Presence of implanted cardiac valves, pacemaker, implantable cardioverters/defibrillators (ICDs) or vena cava filters.
- Subjects with an intra-cardiac mass, tumor, clot or vegetation.
- Large, redundant atrial septal aneurysm that would prohibit adequate device access to the PFO or closure of the PFO, in the judgment of the investigator. A coexisting redundant atrial septal aneurysm is considered large if it prohibits the ability of the operator to adequately achieve vacuum suction necessary to achieve PFO closure.
- Presence of arrhythmia requiring pharmacologic or electrical therapy intervention or 1st degree block.
- Current enrollment in any investigational trial(s) using devices implanted in the vascular system or enrolled in any experimental drug study(ies) within three months of study entry.
- History of stroke or TIA within the past 14 days.
- Source of stroke other than paradoxical embolization.
- Hemodynamic instability or shock.
- Hypercoagulable disorder.
- Subjects with coagulation disorders who are unable to take antiplatelet or anticoagulant therapy.
Key Trial Info
Start Date :
April 1 2005
Trial Type :
INTERVENTIONAL
End Date :
Estimated Enrollment :
40 Patients enrolled
Trial Details
Trial ID
NCT00196027
Start Date
April 1 2005
Last Update
November 29 2006
Active Locations (1)
Enter a location and click search to find clinical trials sorted by distance.
1
CardioVascular Center, Sankt katharinen
Frankfurt am Main, Germany