Status:

UNKNOWN

Cobra II Study: Use of the Cobra™ Cobalt Super Alloy Coronary Stent System in the Treatment of Coronary Artery Disease

Lead Sponsor:

Medlogics Device Corporation

Collaborating Sponsors:

Baim Institute for Clinical Research

Stanford University

Conditions:

Coronary Artery Disease

Eligibility:

All Genders

18+ years

Phase:

PHASE2

Brief Summary

To demonstrate the safety and efficacy of the Cobra Cobalt Super Alloy Balloon-Expandable Coronary Stent System for the treatment of de novo and restenotic (previously unstented) lesions in native cor...

Detailed Description

Safety and Efficacy will be demonstrated by the rate of Target vessel failure (TVF), defined as cardiac death, target vessel myocardial infarction (MI) \[Q wave or non-Q wave\], or clinically driven t...

Eligibility Criteria

Inclusion

  • The subject is ≥ 18 years old;
  • Subject is eligible for percutaneous coronary intervention (PCI), stent placement, and emergent coronary artery bypass graft (CABG) surgery;
  • Subject has clinical evidence of ischemic heart disease, stable or unstable angina or silent ischemia;
  • The subject has a documented left ventricular ejection fraction (LVEF) ≥ 30%;
  • The subject or legal representative has been informed of the clinical study and the required follow-up procedures and must provide written informed consent using a form that is reviewed and approved by the Institutional Review Board/Ethics Committee (IRB/EC) for the clinical site;
  • Female subjects of childbearing potential must have a negative pregnancy test within 7 days before treatment;
  • Subject must agree to comply with the required follow-up procedures (including antiplatelet regimen) to the best of their ability, be geographically available for all study follow-up procedures and visits and not have a known medical condition that precludes completion of the required follow-up visits;
  • The lesion is either de novo or restenotic (previously unstented) in nature, located in a native coronary artery AND is ≥ 50% and \< 100% stenosed by visual estimate or on-line QCA;
  • The target vessel reference diameter ≥ 2.5mm and ≤ 4mm by visual estimate and is appropriate for treatment with available stent diameters of 2.5 mm, to 4.0 mm;
  • The lesion length is ≤ 26 mm and able to accommodate placement of a single stent;
  • The target lesion is a minimum of 15 mm from any previously placed stent; AND
  • The target vessel must have a Thrombolysis In Myocardial Infarction (TIMI) flow ≥ 2

Exclusion

  • The subject has a known hypersensitivity or contraindication to aspirin, heparin and bivalirudin, ticlopidine and clopidogrel, cobalt, nickel, chromium, molybdenum, or a sensitivity to contrast media, which cannot be adequately pre-medicated;
  • A platelet count \< 100,000 cells/mm³ or \> 700,000 cells/mm³, or a WBC \< 3,000 cells/mm³;
  • A creatinine level \> 2.5 mg/dL within 7 days prior to the index procedure;
  • Evidence of an acute myocardial infarction (MI) within 72 hours of the intended treatment (defined as: Q wave (QWMI) or any elevation of creatine kinase myocardial-band (CK-MB) isoenzyme elevated above the Institution's upper limit of normal;
  • Any previous PCI (with or without stent) of the target vessel within 30 days prior to the index procedure;
  • Previous stent placement anywhere in the target lesion;
  • Previous drug eluting stent (DES) deployment anywhere in the target vessel;
  • The subject requires staged procedure of any non-target vessel within 30 days post-procedure;
  • The subject requires staged procedure of the target vessel within 9 months post-procedure;
  • The target lesion requires treatment with a device other than PTCA prior to stent placement (including, but not limited to, cutting balloon, directional coronary atherectomy, excimer laser, rotational atherectomy, thrombectomy, etc.;
  • History of a stroke or transient ischemic attack (TIA) within the previous 6 months;
  • Active peptic ulcer or upper gastrointestinal (GI) bleeding within the previous 6 months;
  • History of bleeding diathesis or coagulopathy or will refuse blood transfusions;
  • A known concurrent medical condition resulting in a life expectancy of less than 12 months;
  • Any previous or planned treatment of the target vessel with anti-restenotic therapies including, but not limited to brachytherapy;
  • The subject is currently participating in another investigational device or drug study and has not completed the primary endpoint(s) follow-up phase of that study at least 30 days prior to enrollment in this trial; or interferes with the current trial endpoints; or the subject has previously been enrolled in the study;
  • The subject has a known medical condition that will cause them to be non-compliant with the study protocol or confound the data interpretation;
  • The target vessel has evidence of thrombus or other lesions having a \> 60% stenosis by visual estimate or on-line QCA;
  • Target vessel exhibiting multiple lesions with greater than 60% diameter stenosis outside of a range of 5 mm proximal and distal to the target lesion based on visual estimate or on-line QCA;
  • The target vessel has evidence (visual or QCA) of excessive tortuosity (two or more 90° bends prior to the target lesion) or is severely calcified; OR
  • The target lesion is in an unprotected left main, involves a side branch vessel having a diameter of \> 2.0 mm or is at the aorto-ostial location

Key Trial Info

Start Date :

August 1 2008

Trial Type :

INTERVENTIONAL

Allocation :

ESTIMATED

End Date :

September 1 2010

Estimated Enrollment :

258 Patients enrolled

Trial Details

Trial ID

NCT00744107

Start Date

August 1 2008

End Date

September 1 2010

Last Update

August 6 2009

Active Locations (7)

Enter a location and click search to find clinical trials sorted by distance.

Page 1 of 2 (7 locations)

1

Main Taunus Kliniken, Kardiologisches

Bad Soden, Germany, 65812

2

St. Vincenz Krankenhaus

Essen, Germany, 45141

3

Krankenhaus der Barmherzigen Brüder

Trier, Germany, 54292

4

Hadassah Hebrew University Medical Center

Jerusalem, Israel, 91120